{"title":"EEG Sensor","description":null,"products":[{"product_id":"disposable-non-invasive-eeg-sensor","title":"Plinma disposable Non-Invasive EEG Sensor","description":"\u003ch2 class=\"title\"\u003eProduct advantages\u003c\/h2\u003e\n\u003cdiv class=\"list\"\u003e\n\u003cp\u003ePlinma Disposable Non-invasive EEG Sensor is easy to use, safe and non-invasive, and ofered in multi specications for both adults and children, including 86A03, 86A04, 86P03, 86P04 and etc.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThrough foreign clinical verification, the sensor signal is stable, and the response is fast. Compared with the original product, the numerical consistency is good. It can accurately reflect the patient's current state of depth of anesthesia.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble shielding technology is used to reduce impedance and reduce interference. Imported conductive glue and sensor components are used to ensure complete and accurate data collection and real-time monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVarious materials of the product have passed rigorous biocompatibility tests. No sensitization.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan be adapted to multi-brand anesthesia depth monitoring equipment (BIS module and GE entropy index module)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: left;\" class=\"title\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 style=\"text-align: left;\" class=\"title\"\u003eTechnical parameter\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"546\" height=\"412\" style=\"border-collapse: collapse; width: 1009px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"260\" style=\"width: 478.5px;\"\u003e\n\u003ccol width=\"286\" style=\"width: 529.5px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"30\" style=\"height: 22.50pt;\"\u003e\n\u003ctd style=\"height: 15.00pt; width: 195.00pt;\" width=\"260\" height=\"20\" class=\"et2\"\u003eAC impedance\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003e≤3KΩ（10Hz）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.00pt;\"\u003e\n\u003ctd style=\"height: 15.00pt; width: 195.00pt;\" width=\"260\" height=\"20\" class=\"et2\"\u003eDC offset voltage\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003e≤100mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.00pt;\"\u003e\n\u003ctd style=\"height: 15.00pt; width: 195.00pt;\" width=\"260\" height=\"20\" class=\"et2\"\u003e\n\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eInternal noise\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003e≤150μV(peak-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.00pt;\"\u003e\n\u003ctd style=\"height: 75.00pt; width: 195.00pt;\" width=\"260\" height=\"100\" class=\"et2\"\u003eSimulated defibrillation recovery performance\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003eThe voltage value of the electrode pair at 5s after discharge is less than or equal to 100mV; the average rate of change after 30s is less than or equal to ±1mV\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"100\" style=\"height: 75.00pt;\"\u003e\n\u003ctd style=\"height: 30.00pt; width: 195.00pt;\" width=\"260\" height=\"40\" class=\"et2\"\u003eSimulated AC impedance after defibrillation\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003e≤3KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"40\" style=\"height: 30.00pt;\"\u003e\n\u003ctd style=\"height: 15.00pt; width: 195.00pt;\" width=\"260\" height=\"20\" class=\"et2\"\u003eBias current tolerance\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003e≤100mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.00pt;\"\u003e\n\u003ctd style=\"height: 30.00pt; width: 195.00pt;\" width=\"260\" height=\"40\" class=\"et2\"\u003eCytotoxicity test\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003eThe cytotoxicity score is not greater than 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"40\" style=\"height: 30.00pt;\"\u003e\n\u003ctd style=\"height: 15.00pt; width: 195.00pt;\" width=\"260\" height=\"20\" class=\"et2\"\u003eDelayed type hypersensitivity test\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003eNo sensitization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.00pt;\"\u003e\n\u003ctd style=\"height: 15.00pt; width: 195.00pt;\" width=\"260\" height=\"20\" class=\"et2\"\u003eSkin irritation test\u003c\/td\u003e\n\u003ctd style=\"width: 214.50pt;\" width=\"286\" class=\"et3\"\u003eVery slight irritation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Plinma","offers":[{"title":"Default Title","offer_id":41823474647134,"sku":"","price":10.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2527\/9582\/files\/20250627185815.png?v=1751023044"}],"url":"https:\/\/plinma.com\/collections\/eeg-sensor.oembed","provider":"Plinma","version":"1.0","type":"link"}